Is your Blue Star AC outdoor unit not working? Let’s learn how to fix the H6 Error with this simple Blue Star AC solution guide.
When a Blue Star AC suddenly stops cooling and shows the H6 error, also known as the Blue Star AC H6 error code, it usually happens at the most inconvenient moment—right when the heat is unbearable.

Because this issue often appears in both Blue Star split AC H6 error cases and Blue Star inverter AC H6 error code situations, many users feel stressed immediately.
However, the good news is that the problem usually links to one specific internal component that you can inspect yourself.
The H6 error in Blue Star AC is closely linked to the position detection sensor, a critical device responsible for monitoring how moving parts stay aligned. Since this sensor acts like a feedback sensor or RPM sensor fault monitor, the AC shuts down when the readings are incorrect.
This guide explains exactly what the error means, how to fix it, and when to involve a technician.
What is the H6 Error in Blue Star AC?
The Blue Star AC error code H6 meaning points to a position detection sensor malfunction. Because this sensor relies on motor rotation data, any AC blower jammed, fan motor malfunction, or indoor fan motor error directly affects readings.
This sensor monitors:
- The alignment of moving parts
- The louver motion
- The indoor fan motor speed
- The synchronization of components
Whenever the sensor fails to send correct data, the AC enters protection mode, resulting in the H6 error code in Blue Star inverter AC or any other model.
Tip: If your AC starts slowly or the blower hesitates, the sensor may be misreading fan rotation.
Behind the scenes, your AC is signaling that something isn’t moving or aligning the way it should. In most cases, the fault directly traces back to the position detection sensor, which plays a major role in reading movement alignment. Since the AC depends heavily on this feedback, any sensor failure forces the system to shut down as a safety measure.
Why is your Blue Star AC Showing H6?
The H6 error code indicates that the AC has detected a malfunction in the position detection sensor. This sensor continually checks:
- The alignment of moving components
- The movement of louvers
- The rotation speed and position of the indoor fan
- The synchronized movement of all connected mechanisms
Therefore, whenever the sensor fails to send accurate feedback, the AC immediately enters protection mode and displays the H6 error. This is done to prevent issues such as fan motor overload, jamming louvers, or mechanical wear.
Additionally, several error lists also associate H6 with fan motor feedback issues, which makes sense because misalignment or sensor failure affects how the AC interprets fan movement.
Tip: If you notice slow, noisy, or irregular fan movement, this may directly influence sensor readings.
How to Fix H6 Error in Blue Star AC
The following steps will help you diagnose the issue effectively. Because safety is critical, follow each step carefully and in order.

Step 1: Power Off and Unplug the AC for Safety
First, turn off the AC completely and unplug it from the power outlet. Additionally, wait 5–10 minutes to allow internal circuits to discharge fully. Without this pause, internal electricity may remain stored, which can be risky.
Tip: If a stabilizer is connected, switch it off as well.
Step 2: Locate the Position Detection Sensor Inside the Unit
Next, open the indoor unit’s front panel. Inside, you should find the position detection sensor near:
- The louver motor
- The fan blower assembly
- Any moving mechanism
Some models place the sensor deeper inside the blower housing, so the manual may help you locate it.
Tip: Before touching anything, take a clear photo to remember wire placement.
Step 3: Clean the Sensor and Surrounding Area Thoroughly
Now gently clean the:
- Sensor surface
- Louver rotation area
- Fan blower housing
- Wiring pathways
Dust accumulation is one of the most common reasons for the H6 error; therefore, cleaning often fixes the issue quickly.
Tip: Never use water or sprays; moisture can damage internal circuits instantly
Step 4: Inspect Wiring Connections Connected to the Sensor
Next, carefully examine:
- Loose connectors
- Burn marks
- Melted insulation
- Corroded terminals
- Exposed wires
Because wiring issues frequently cause intermittent H6 errors, secure all connectors firmly.
Safety Tip: If you see burnt or melted wiring, stop immediately and call a technician.
Step 5: Evaluate the Physical Condition of the Sensor
Finally, check the sensor for:
- Cracks
- Burn marks
- Corrosion
- Non-responsive behavior
If the AC does not react when you manually move the blower or louvers during testing, the sensor is failing.
Tip: Use a flashlight to inspect the sensor surface carefully.
How to Reset Blue Star Inverter AC After Fixing H6 Error
After cleaning or replacing the sensor:
- Plug the AC back in.
- Turn it on using the remote.
- Let it run a diagnostic cycle, if supported.
- Observe the fan rotation, louver motion, and cooling airflow.
- Confirm that the H6 error does not return.
Allow the AC to run for at least 10–15 minutes to ensure stable performance.
Tip: If the fan hesitates during startup, the motor may have resistance and needs further inspection.
When to Call a Technician for Blue Star AC H6 Error Repair
You should call a professional technician for your Blue Star AC when any of the following scenarios occur:
- The H6 error persists even after you’ve followed all troubleshooting steps.
- You notice burnt wiring, melted insulation, or scorched connectors inside the indoor unit—these signs often indicate deeper electrical or PCB-related issues.
- The indoor fan is not spinning at all, despite no visible dust or obstruction. This may point to a dead motor or a fault within the controller.
- The louvers are stuck, clicking, or vibrating—a clear indication of mechanical misalignment or motor failure behind the sensor fault.
- The sensor location is difficult to access or dismantle safely—professional training is required.
- You see multiple error codes appear, or you suspect the PCB circuit board repair is needed rather than just a sensor or wiring fix.
- Your unit is under warranty and opening the indoor unit yourself may void the warranty terms. In that case, opting for authorised service is strongly recommended.
For official support from Blue Star, you can visit their Service & Support page here: Blue Star Service & Support Blue Star
Tip: When you contact the service centre, be ready with your AC model number, serial number, current error code (H6), and a brief description of what you have already done (cleaned sensor, checked wiring, etc.). This helps the technician prepare the correct spare parts and ensure faster resolution—reducing downtime and additional costs.
fAQ About H6 Error in Blue Star AC
Is the H6 error dangerous?
No, but it does prevent normal operation.
Can I continue using the AC with this error?
No. The AC may shut off suddenly or strain internal parts.
Does it affect all Blue Star models?
Yes. Both inverter and non-inverter models rely on position detection sensors.
How long does repair take?
Cleaning takes minutes; replacement takes 20–40 minutes.
Is replacing the sensor a permanent fix?
Yes—unless there is deeper wiring or PCB damage.
Conclusion: Fixing and Preventing the H6 Error in Blue Star AC
The H6 error in Blue Star AC almost always points to a malfunctioning position detection sensor or nearby components. Fortunately, most fixes are simple—whether it’s cleaning dust, tightening wiring, or replacing the sensor.
With consistent care, quick response, and proper maintenance, you can prevent the error from returning and keep the AC running efficiently during peak summer months.
Tip: If the H6 error returns even after several days, schedule a complete internal inspection to identify hidden issues like motor resistance or PCB abnormalities.
Visit Our Post Page: Blog Page